I-PEX 20878 CABLINE-UM Plug Housing for Micro-Coax Harnesses
The I-PEX 20878 is the plug housing in the CABLINE-UM family, which uses a 0.4 mm contact pitch and right-angle vertical mating. PrecisionCoax builds custom micro-coax cable harnesses for this connector system for projects such as high-pin-count module interconnects, internal display wiring, and shielded multi-signal harnesses.
Connector Selection at a Glance
- Connector family I-PEX CABLINE-UM.
- Listed contact counts 30, 40, 50, 60, 70.
- Selection notes Use the housing number to identify the contact set and its plug configuration. A finished cable drawing should also identify the metal shell, retention hardware where applicable, and board receptacle.
I-PEX 20878 Part Numbers and Connector Options
The 20878 is the cable-side housing used in 20877 plug configurations. The product list shows 30-, 40-, 50-, 60-, and 70-position -01 housings, as well as selected -11 variants.
Related part families include 20877 (cable-side plug), 20879 (PCB receptacle).
The following are publicly documented part numbers, including some earlier variants. Confirm the exact suffix and availability for your project.
- 30 positions: 20878-030T-01
- 40 positions: 20878-040T-01, 20878-040T-11
- 50 positions: 20878-050T-01
- 60 positions: 20878-060T-01, 20878-060T-11
- 70 positions: 20878-070T-01
Wire Selection and Custom Harness Options
I-PEX documentation for CABLINE-UM references micro-coaxial wire in 36, 38, 40, 42, and 44 AWG. Final wire selection depends on the exact connector, cable outer diameter, termination dimensions, and electrical requirements.
For a complete micro-coax harness, identify the plug housing, shell, mating receptacle, and any retention hardware. We review conductor sizes, cable exit direction, and the shield termination shown in the drawing.
Provide the clearance above the board, the cable exit direction, and access for the selected lock cover or pull tape. These details affect assembly and service access.
Specify the preferred sleeving, cable jacket, shield grounding, and routing. Inspection requirements can include pin-to-pin continuity, shorts, and shield continuity.
Common Harness Designs Using This Housing
High-position-count internal interconnect
Group the pin map by signal, power, return, and shield. Show the harness bundle dimensions and supported attachment points in the enclosure.
Shielded display or module harness
Check vertical mating clearance and service access when choosing the lock cover or pull-tape configuration. Identify the allowed cable exit angle after installation.
What to Put on the Cable Assembly Drawing
- Connector and mating views Record the manufacturer and full part number at each end. Mark pin 1 and state whether each diagram shows the mating face or the wire-entry side.
- Pin assignments List every populated contact, pair polarity, power and ground positions, and intentional opens. State whether the cable is straight-through or uses a custom pin map.
- Wire and impedance Specify wire type, AWG or approved wire part number, and single-ended or differential impedance as applicable. Include length matching or skew limits when required.
- Length and routing Define the measurement points, finished length tolerance, cable breakout, and exit direction. Include bends, pass-through dimensions, and any moving sections.
- Shielding and protection Define individual shield and shell connections at both ends. Specify sleeve type, wrapping, jacket, labels, and strain relief where needed.
Prototype Review and Production Checks
- First article Review the mating fit, cable routing, connector orientation, and overall dimensions against the drawing before releasing the production configuration.
- Electrical inspection Specify pin-to-pin continuity, shorts between conductors, and shield continuity. Where the drawing calls for isolation, identify the relevant conductors and limits.
- Signal integrity If the project requires impedance, insertion loss, or skew measurements, state the test method, reference points, and acceptance limits in the RFQ.
Frequently Asked Questions
What should I include if my BOM lists only the plug housing?
Provide the housing suffix, the board receptacle number, and any shell or latch information from the original assembly. Photos of an assembled plug can help identify missing BOM details.
What should I check when changing the retention configuration?
Confirm how the selected cover or pull tape fits the existing plug and board-side parts. Check access for installation and removal with the enclosure assembled.
Can I use fewer wires than the connector has positions?
Yes, if your design allows it. Mark intentionally unpopulated positions and specify any grounds or shields that still need termination. Send the full pin map for both ends so the wiring can be checked before production.
Request an I-PEX 20878 Cable Assembly Quote