Micro Coaxial Cable Processing Specialist

Room 409, Room 4, Hatching Building, No. 98 Xiongtian Road, Longping High-tech Park, Furong District, Changsha City, Changsha City

© Copyright 2025 PrecisionCoax

I-PEX 20790 CABLINE-CA II PLUS PCB Receptacle & Mating Cable
I-PEX 20790 CABLINE-CA II PLUS PCB receptacle and mating micro-coax cable. Compare models including 20790-060E-01 and request a custom harness quote.
  • Country of Origin: China
  • Certification: UL, ISO13485, ISO9001
  • MOQ: negotiable
  • Price: Best price
  • Packaging details: PE inner layer, carton outer layer
  • Delivery time: 7-15 days after payment received
  • Payment method: T/T, Western Union
  • Supply capacity: 500,000 pieces/week

Partner Brands

I-PEX 20790 CABLINE-CA II PLUS PCB Receptacle for Micro-Coax Harnesses

The I-PEX 20790 is the PCB receptacle in the CABLINE-CA II PLUS family, which uses a 0.4 mm contact pitch and horizontal mating. PrecisionCoax builds custom micro-coax cable harnesses for this connector system for projects such as 60-position shielded interconnects for embedded systems and high-speed test assemblies.

Connector Selection at a Glance

  • Connector family I-PEX CABLINE-CA II PLUS.
  • Listed contact counts 60.
  • Selection notes The part number identifies the PCB-side interface. Use it to confirm the mating cable-side plug. For existing boards, include the board revision and a clear mating-face photo.

I-PEX 20790 Part Numbers and Connector Options

The 20790 is the 60-position board receptacle. I-PEX lists 20790-060E-01 with a locating boss and 20790-060E-02 without one. Include the exact suffix when identifying the board or replacing the harness.

Related part families include 20788 (cable-side plug), 20789 (lock bar assembly).

The following are publicly documented part numbers, including some earlier variants. Confirm the exact suffix and availability for your project.

  • 60 positions: 20790-060E-01, 20790-060E-01-S, 20790-060E-02, 20790-060E-02-S, 20790-060E-11, 20790-060E-12

Wire Selection and Custom Harness Options

I-PEX documentation for CABLINE-CA II PLUS references micro-coaxial wire in 36, 38, 40, 42, and 44 AWG. Final wire selection depends on the exact connector, cable outer diameter, termination dimensions, and electrical requirements.

A receptacle number identifies the board interface. We use it to check the cable-side plug and then build the micro-coax harness to the pinout and cable routing you specify.

For a high-speed or mixed-signal harness, specify pair mapping, target impedance, shield connections, and any pair-to-pair length matching in the cable drawing.

Specify the preferred sleeving, cable jacket, shield grounding, and routing. Inspection requirements can include pin-to-pin continuity, shorts, and shield continuity.

Applications for the Mating Cable Assembly

60-position module interconnect

Identify all differential pairs and their polarity, power and return positions, and any dedicated grounds. Show where the harness crosses chassis or board boundaries.

High-speed evaluation or test cable

Document both mating interfaces, the required test reference planes, and any insertion loss, impedance, or skew criteria that apply to the finished assembly.

What to Put on the Cable Assembly Drawing

  • Connector and mating views Record the manufacturer and full part number at each end. Mark pin 1 and state whether each diagram shows the mating face or the wire-entry side.
  • Pin assignments List every populated contact, pair polarity, power and ground positions, and intentional opens. State whether the cable is straight-through or uses a custom pin map.
  • Wire and impedance Specify wire type, AWG or approved wire part number, and single-ended or differential impedance as applicable. Include length matching or skew limits when required.
  • Length and routing Define the measurement points, finished length tolerance, cable breakout, and exit direction. Include bends, pass-through dimensions, and any moving sections.
  • Shielding and protection Define individual shield and shell connections at both ends. Specify sleeve type, wrapping, jacket, labels, and strain relief where needed.

Prototype Review and Production Checks

  • First article Review the mating fit, cable routing, connector orientation, and overall dimensions against the drawing before releasing the production configuration.
  • Electrical inspection Specify pin-to-pin continuity, shorts between conductors, and shield continuity. Where the drawing calls for isolation, identify the relevant conductors and limits.
  • Signal integrity If the project requires impedance, insertion loss, or skew measurements, state the test method, reference points, and acceptance limits in the RFQ.

Frequently Asked Questions

Can I order a harness from the PCB receptacle part number alone?

The receptacle is a starting point for selecting the mating plug. A harness quote also needs the second connector or termination, finished length, pin map, and cable requirements.

What information is needed for a 60-position cable replacement?

Specify the complete plug and receptacle numbers, exact lock bar configuration, and the original pin map. Include a locating-boss requirement if it applies to the board.

Can I use fewer wires than the connector has positions?

Yes, if your design allows it. Mark intentionally unpopulated positions and specify any grounds or shields that still need termination. Send the full pin map for both ends so the wiring can be checked before production.

Request an I-PEX 20790 Cable Assembly Quote

Send the full receptacle number, the connector at the opposite end, the two pinouts, finished cable length, and order quantities. If a drawing is unavailable, send clear photographs of both connector faces, cable labels, and the original assembly.

Product Ordering Guidelines

For Existing Product Designs or Samples

If you already have product drawings or physical samples, simply provide them to us, and we can proceed with production.

Custom Product Development (No Existing Reference)

If you need to develop a new product without existing samples or drawings, please provide the following details for our design team to create a tailored solution:
a. Electrical Requirements: Operating current and voltage.
b. Connector Specifications: Model numbers, samples, or specifications for connectors at both ends of the cable.
c. Pin Configuration: Pin-to-pin correspondence for the cable assembly.
d. Environmental Conditions: Application scenario (e.g., lawn mowers, mining equipment) and required certifications (oil resistance, waterproofing, high-temperature tolerance, flexing tests, etc.).
e. Electrical Testing Requirements: Transmission characteristics, voltage withstand, conduction resistance, insulation resistance, etc.

Custom Cables & Solutions

Specializing in small-batch, multi-variety production! We offer end-to-end services, from new product introduction to mass production.

Core Advantages

✓ 20+ Years of Brand-Component Distribution Expertise
✓ 100% Genuine Components Direct from Original Manufacturers
✓ Expert Product Selection & Matching Services

Rapid Delivery from Stock

Domestic Warehouse: Orders placed today, shipped tomorrow.
International Warehouse: Orders placed today, delivered in 6-10 days.

Ordering Flexibility

✓ Minimum Order: 1 unit
✓ Small-Batch Samples: Available from 1 unit
✓ Large-Scale Orders: Standard lead time from original manufacturers.

Key Features

✓ Minimum Order: 1 unit
Small-Quantity Friendly: Ideal for prototyping and niche projects.
Bulk Order Efficiency: Seamless scaling from trial to mass production.

Scroll