Micro Coaxial Cable Processing Specialist

Room 409, Room 4, Hatching Building, No. 98 Xiongtian Road, Longping High-tech Park, Furong District, Changsha City, Changsha City

© Copyright 2025 PrecisionCoax

I-PEX 20789 CABLINE-CA II PLUS Lock Bar & Cable Assembly
I-PEX 20789 CABLINE-CA II PLUS lock bar for micro-coax cable assemblies. See 20789-060T-01, compatible plug parts, and custom harness options.
  • Country of Origin: China
  • Certification: UL, ISO13485, ISO9001
  • MOQ: negotiable
  • Price: Best price
  • Packaging details: PE inner layer, carton outer layer
  • Delivery time: 7-15 days after payment received
  • Payment method: T/T, Western Union
  • Supply capacity: 500,000 pieces/week

Partner Brands

I-PEX 20789 CABLINE-CA II PLUS Lock Bar Assembly for Micro-Coax Harnesses

The I-PEX 20789 is the lock bar assembly in the CABLINE-CA II PLUS family, which uses a 0.4 mm contact pitch and horizontal mating. PrecisionCoax builds custom micro-coax cable harnesses for this connector system for projects such as 60-position shielded interconnects for embedded systems and high-speed test assemblies.

Connector Selection at a Glance

  • Connector family I-PEX CABLINE-CA II PLUS.
  • Listed contact counts 60.
  • Selection notes The lock bar is one part of the cable-side plug assembly. For installed equipment, check the path needed to engage and release it, including enclosure and bundle clearance.

I-PEX 20789 Part Numbers and Connector Options

I-PEX lists the 20789-060T-01 lock bar without pull tape and the 20789-060T-02 version with pull tape. Specify access to the pull tape or release area in the installed enclosure.

Related part families include 20788 (cable-side plug), 20680 (plug housing), 20790 (PCB receptacle).

The following are publicly documented part numbers, including some earlier variants. Confirm the exact suffix and availability for your project.

  • 60 positions: 20789-060T-01, 20789-060T-02

Wire Selection and Custom Harness Options

I-PEX documentation for CABLINE-CA II PLUS references micro-coaxial wire in 36, 38, 40, 42, and 44 AWG. Final wire selection depends on the exact connector, cable outer diameter, termination dimensions, and electrical requirements.

When ordering a finished harness, identify the plug housing, lock bar and board receptacle. Include the latch release direction and any pull-tape length or routing requirements in the mechanical drawing.

For a high-speed or mixed-signal harness, specify pair mapping, target impedance, shield connections, and any pair-to-pair length matching in the cable drawing.

Specify the preferred sleeving, cable jacket, shield grounding, and routing. Inspection requirements can include pin-to-pin continuity, shorts, and shield continuity.

Harness Applications and Service Access

60-position module interconnect

Identify all differential pairs and their polarity, power and return positions, and any dedicated grounds. Show where the harness crosses chassis or board boundaries.

High-speed evaluation or test cable

Document both mating interfaces, the required test reference planes, and any insertion loss, impedance, or skew criteria that apply to the finished assembly.

What to Put on the Cable Assembly Drawing

  • Connector and mating views Record the manufacturer and full part number at each end. Mark pin 1 and state whether each diagram shows the mating face or the wire-entry side.
  • Pin assignments List every populated contact, pair polarity, power and ground positions, and intentional opens. State whether the cable is straight-through or uses a custom pin map.
  • Wire and impedance Specify wire type, AWG or approved wire part number, and single-ended or differential impedance as applicable. Include length matching or skew limits when required.
  • Length and routing Define the measurement points, finished length tolerance, cable breakout, and exit direction. Include bends, pass-through dimensions, and any moving sections.
  • Shielding and protection Define individual shield and shell connections at both ends. Specify sleeve type, wrapping, jacket, labels, and strain relief where needed.

Prototype Review and Production Checks

  • First article Review the mating fit, cable routing, connector orientation, and overall dimensions against the drawing before releasing the production configuration.
  • Electrical inspection Specify pin-to-pin continuity, shorts between conductors, and shield continuity. Where the drawing calls for isolation, identify the relevant conductors and limits.
  • Signal integrity If the project requires impedance, insertion loss, or skew measurements, state the test method, reference points, and acceptance limits in the RFQ.

Frequently Asked Questions

How do I specify the lock bar on a cable drawing?

List the complete lock bar and housing part numbers, and show the access direction. If a pull tape is specified, mark its exit direction and the room available to grasp it.

What information is needed for a 60-position cable replacement?

Specify the complete plug and receptacle numbers, exact lock bar configuration, and the original pin map. Include a locating-boss requirement if it applies to the board.

Can I use fewer wires than the connector has positions?

Yes, if your design allows it. Mark intentionally unpopulated positions and specify any grounds or shields that still need termination. Send the full pin map for both ends so the wiring can be checked before production.

Request an I-PEX 20789 Cable Assembly Quote

Send the lock bar, housing, and receptacle part numbers, plus the wire gauge, pin map, finished length, and desired quantities. If a drawing is unavailable, send clear photographs of both connector faces, cable labels, and the original assembly.

Product Ordering Guidelines

For Existing Product Designs or Samples

If you already have product drawings or physical samples, simply provide them to us, and we can proceed with production.

Custom Product Development (No Existing Reference)

If you need to develop a new product without existing samples or drawings, please provide the following details for our design team to create a tailored solution:
a. Electrical Requirements: Operating current and voltage.
b. Connector Specifications: Model numbers, samples, or specifications for connectors at both ends of the cable.
c. Pin Configuration: Pin-to-pin correspondence for the cable assembly.
d. Environmental Conditions: Application scenario (e.g., lawn mowers, mining equipment) and required certifications (oil resistance, waterproofing, high-temperature tolerance, flexing tests, etc.).
e. Electrical Testing Requirements: Transmission characteristics, voltage withstand, conduction resistance, insulation resistance, etc.

Custom Cables & Solutions

Specializing in small-batch, multi-variety production! We offer end-to-end services, from new product introduction to mass production.

Core Advantages

✓ 20+ Years of Brand-Component Distribution Expertise
✓ 100% Genuine Components Direct from Original Manufacturers
✓ Expert Product Selection & Matching Services

Rapid Delivery from Stock

Domestic Warehouse: Orders placed today, shipped tomorrow.
International Warehouse: Orders placed today, delivered in 6-10 days.

Ordering Flexibility

✓ Minimum Order: 1 unit
✓ Small-Batch Samples: Available from 1 unit
✓ Large-Scale Orders: Standard lead time from original manufacturers.

Key Features

✓ Minimum Order: 1 unit
Small-Quantity Friendly: Ideal for prototyping and niche projects.
Bulk Order Efficiency: Seamless scaling from trial to mass production.

Scroll