I-PEX 20789 CABLINE-CA II PLUS Lock Bar Assembly for Micro-Coax Harnesses
The I-PEX 20789 is the lock bar assembly in the CABLINE-CA II PLUS family, which uses a 0.4 mm contact pitch and horizontal mating. PrecisionCoax builds custom micro-coax cable harnesses for this connector system for projects such as 60-position shielded interconnects for embedded systems and high-speed test assemblies.
Connector Selection at a Glance
- Connector family I-PEX CABLINE-CA II PLUS.
- Listed contact counts 60.
- Selection notes The lock bar is one part of the cable-side plug assembly. For installed equipment, check the path needed to engage and release it, including enclosure and bundle clearance.
I-PEX 20789 Part Numbers and Connector Options
I-PEX lists the 20789-060T-01 lock bar without pull tape and the 20789-060T-02 version with pull tape. Specify access to the pull tape or release area in the installed enclosure.
Related part families include 20788 (cable-side plug), 20680 (plug housing), 20790 (PCB receptacle).
The following are publicly documented part numbers, including some earlier variants. Confirm the exact suffix and availability for your project.
- 60 positions: 20789-060T-01, 20789-060T-02
Wire Selection and Custom Harness Options
I-PEX documentation for CABLINE-CA II PLUS references micro-coaxial wire in 36, 38, 40, 42, and 44 AWG. Final wire selection depends on the exact connector, cable outer diameter, termination dimensions, and electrical requirements.
When ordering a finished harness, identify the plug housing, lock bar and board receptacle. Include the latch release direction and any pull-tape length or routing requirements in the mechanical drawing.
For a high-speed or mixed-signal harness, specify pair mapping, target impedance, shield connections, and any pair-to-pair length matching in the cable drawing.
Specify the preferred sleeving, cable jacket, shield grounding, and routing. Inspection requirements can include pin-to-pin continuity, shorts, and shield continuity.
Harness Applications and Service Access
60-position module interconnect
Identify all differential pairs and their polarity, power and return positions, and any dedicated grounds. Show where the harness crosses chassis or board boundaries.
High-speed evaluation or test cable
Document both mating interfaces, the required test reference planes, and any insertion loss, impedance, or skew criteria that apply to the finished assembly.
What to Put on the Cable Assembly Drawing
- Connector and mating views Record the manufacturer and full part number at each end. Mark pin 1 and state whether each diagram shows the mating face or the wire-entry side.
- Pin assignments List every populated contact, pair polarity, power and ground positions, and intentional opens. State whether the cable is straight-through or uses a custom pin map.
- Wire and impedance Specify wire type, AWG or approved wire part number, and single-ended or differential impedance as applicable. Include length matching or skew limits when required.
- Length and routing Define the measurement points, finished length tolerance, cable breakout, and exit direction. Include bends, pass-through dimensions, and any moving sections.
- Shielding and protection Define individual shield and shell connections at both ends. Specify sleeve type, wrapping, jacket, labels, and strain relief where needed.
Prototype Review and Production Checks
- First article Review the mating fit, cable routing, connector orientation, and overall dimensions against the drawing before releasing the production configuration.
- Electrical inspection Specify pin-to-pin continuity, shorts between conductors, and shield continuity. Where the drawing calls for isolation, identify the relevant conductors and limits.
- Signal integrity If the project requires impedance, insertion loss, or skew measurements, state the test method, reference points, and acceptance limits in the RFQ.
Frequently Asked Questions
How do I specify the lock bar on a cable drawing?
List the complete lock bar and housing part numbers, and show the access direction. If a pull tape is specified, mark its exit direction and the room available to grasp it.
What information is needed for a 60-position cable replacement?
Specify the complete plug and receptacle numbers, exact lock bar configuration, and the original pin map. Include a locating-boss requirement if it applies to the board.
Can I use fewer wires than the connector has positions?
Yes, if your design allows it. Mark intentionally unpopulated positions and specify any grounds or shields that still need termination. Send the full pin map for both ends so the wiring can be checked before production.
Request an I-PEX 20789 Cable Assembly Quote
Send the lock bar, housing, and receptacle part numbers, plus the wire gauge, pin map, finished length, and desired quantities. If a drawing is unavailable, send clear photographs of both connector faces, cable labels, and the original assembly.