Micro Coaxial Cable Processing Specialist

Room 409, Room 4, Hatching Building, No. 98 Xiongtian Road, Longping High-tech Park, Furong District, Changsha City, Changsha City

© Copyright 2025 PrecisionCoax

I-PEX 20777 CABLINE-CAL Plug Housing & Cable Harness
I-PEX 20777 CABLINE-CAL plug housing and custom micro-coax harnesses. Review models including 20777-030T-01, mating parts, and cable options.
  • Country of Origin: China
  • Certification: UL, ISO13485, ISO9001
  • MOQ: negotiable
  • Price: Best price
  • Packaging details: PE inner layer, carton outer layer
  • Delivery time: 7-15 days after payment received
  • Payment method: T/T, Western Union
  • Supply capacity: 500,000 pieces/week

Partner Brands

I-PEX 20777 CABLINE-CAL Plug Housing for Micro-Coax Harnesses

The I-PEX 20777 is the plug housing in the CABLINE-CAL family, which uses a 0.4 mm contact pitch and horizontal mating. PrecisionCoax builds custom micro-coax cable harnesses for this connector system for projects such as retained display harnesses, embedded imaging equipment, and compact industrial electronics.

Connector Selection at a Glance

  • Connector family I-PEX CABLINE-CAL.
  • Listed contact counts 30, 40.
  • Selection notes Use the housing number to identify the contact set and its plug configuration. A finished cable drawing should also identify the metal shell, retention hardware where applicable, and board receptacle.

I-PEX 20777 Part Numbers and Connector Options

The 20777 is the plug housing used in CABLINE-CAL 20728 cable-side assemblies. The published parts include 30- and 40-position dimensions and multiple suffixes. Check the housing revision against the wire-end drawing.

Related part families include 20728 (cable-side plug), 20729 (PCB receptacle).

The following are publicly documented part numbers, including some earlier variants. Confirm the exact suffix and availability for your project.

  • 30 positions: 20777-030T-01, 20777-030T-11
  • 40 positions: 20777-040T-01, 20777-040T-11

Wire Selection and Custom Harness Options

I-PEX documentation for CABLINE-CAL references micro-coaxial wire in 38, 40, 42, and 44 AWG, depending on the application. Final wire selection depends on the exact connector, cable outer diameter, termination dimensions, and electrical requirements.

For a complete micro-coax harness, identify the plug housing, shell, mating receptacle, and any retention hardware. We review conductor sizes, cable exit direction, and the shield termination shown in the drawing.

Check that the latch can be operated with the enclosure assembled. If the harness carries power and signals together, identify supply, return, and shield positions in the drawing.

Specify the preferred sleeving, cable jacket, shield grounding, and routing. Inspection requirements can include pin-to-pin continuity, shorts, and shield continuity.

Common Harness Designs Using This Housing

Retained panel-to-controller cable

Show the insertion direction and how the connector can be reached once the display is installed. Specify the permitted cable exit and first bend.

Mixed-signal industrial harness

Identify signal, supply, return, and shield positions. Provide current requirements for power pins and the routing constraints near the connector.

What to Put on the Cable Assembly Drawing

  • Connector and mating views Record the manufacturer and full part number at each end. Mark pin 1 and state whether each diagram shows the mating face or the wire-entry side.
  • Pin assignments List every populated contact, pair polarity, power and ground positions, and intentional opens. State whether the cable is straight-through or uses a custom pin map.
  • Wire and impedance Specify wire type, AWG or approved wire part number, and single-ended or differential impedance as applicable. Include length matching or skew limits when required.
  • Length and routing Define the measurement points, finished length tolerance, cable breakout, and exit direction. Include bends, pass-through dimensions, and any moving sections.
  • Shielding and protection Define individual shield and shell connections at both ends. Specify sleeve type, wrapping, jacket, labels, and strain relief where needed.

Prototype Review and Production Checks

  • First article Review the mating fit, cable routing, connector orientation, and overall dimensions against the drawing before releasing the production configuration.
  • Electrical inspection Specify pin-to-pin continuity, shorts between conductors, and shield continuity. Where the drawing calls for isolation, identify the relevant conductors and limits.
  • Signal integrity If the project requires impedance, insertion loss, or skew measurements, state the test method, reference points, and acceptance limits in the RFQ.

Frequently Asked Questions

What should I include if my BOM lists only the plug housing?

Provide the housing suffix, the board receptacle number, and any shell or latch information from the original assembly. Photos of an assembled plug can help identify missing BOM details.

What should be checked when copying an existing CABLINE-CAL cable?

Confirm the 30- or 40-position interface, the latch orientation, and the wiring at both ends. Send an existing sample or mating-face photos if the drawing is unavailable.

Can I use fewer wires than the connector has positions?

Yes, if your design allows it. Mark intentionally unpopulated positions and specify any grounds or shields that still need termination. Send the full pin map for both ends so the wiring can be checked before production.

Request an I-PEX 20777 Cable Assembly Quote

Send the full housing number, plug or shell numbers if available, mating receptacle, cable length, pin map, and required quantities. If a drawing is unavailable, send clear photographs of both connector faces, cable labels, and the original assembly.

Product Ordering Guidelines

For Existing Product Designs or Samples

If you already have product drawings or physical samples, simply provide them to us, and we can proceed with production.

Custom Product Development (No Existing Reference)

If you need to develop a new product without existing samples or drawings, please provide the following details for our design team to create a tailored solution:
a. Electrical Requirements: Operating current and voltage.
b. Connector Specifications: Model numbers, samples, or specifications for connectors at both ends of the cable.
c. Pin Configuration: Pin-to-pin correspondence for the cable assembly.
d. Environmental Conditions: Application scenario (e.g., lawn mowers, mining equipment) and required certifications (oil resistance, waterproofing, high-temperature tolerance, flexing tests, etc.).
e. Electrical Testing Requirements: Transmission characteristics, voltage withstand, conduction resistance, insulation resistance, etc.

Custom Cables & Solutions

Specializing in small-batch, multi-variety production! We offer end-to-end services, from new product introduction to mass production.

Core Advantages

✓ 20+ Years of Brand-Component Distribution Expertise
✓ 100% Genuine Components Direct from Original Manufacturers
✓ Expert Product Selection & Matching Services

Rapid Delivery from Stock

Domestic Warehouse: Orders placed today, shipped tomorrow.
International Warehouse: Orders placed today, delivered in 6-10 days.

Ordering Flexibility

✓ Minimum Order: 1 unit
✓ Small-Batch Samples: Available from 1 unit
✓ Large-Scale Orders: Standard lead time from original manufacturers.

Key Features

✓ Minimum Order: 1 unit
Small-Quantity Friendly: Ideal for prototyping and niche projects.
Bulk Order Efficiency: Seamless scaling from trial to mass production.

Scroll