PrecisionCoax builds custom micro-coaxial cable assemblies using the I-PEX 20728 CABLINE-CAL cable-side plug. The family uses a 0.4 mm contact pitch with horizontal mating and can be evaluated for retained display harnesses, embedded imaging equipment, and compact industrial electronics.
Connector Selection at a Glance
- Connector family I-PEX CABLINE-CAL.
- Listed contact counts 30, 40.
- Selection notes The plug part number identifies the cable-side termination. Use the confirmed plug and board receptacle combination before choosing a cable layout.
I-PEX 20728 Part Numbers and Connector Options
The 20728-030T-01 and 20728-040T-01 identify the 30- and 40-position CABLINE-CAL plugs. Match the plug to the corresponding 20729 board receptacle and call out the 20777 housing version where required.
Related part families include 20777 (plug housing), 20729 (PCB receptacle).
The following are publicly documented part numbers, including some earlier variants. Confirm the exact suffix and availability for your project.
- 30 positions: 20728-030T-01
- 40 positions: 20728-040T-01
Wire Selection and Custom Harness Options
I-PEX documentation for CABLINE-CAL references micro-coaxial wire in 38, 40, 42, and 44 AWG, depending on the application. Final wire selection depends on the exact connector, cable outer diameter, termination dimensions, and electrical requirements.
Specify the finished length, plug orientation at each end, and straight-through or custom pin mapping. If the opposite end uses a different connector, include its exact part number and mating view.
Check that the latch can be operated with the enclosure assembled. If the harness carries power and signals together, identify supply, return, and shield positions in the drawing.
Specify the preferred sleeving, cable jacket, shield grounding, and routing. Inspection requirements can include pin-to-pin continuity, shorts, and shield continuity.
Typical Cable Assembly Applications
Retained panel-to-controller cable
Show the insertion direction and how the connector can be reached once the display is installed. Specify the permitted cable exit and first bend.
Mixed-signal industrial harness
Identify signal, supply, return, and shield positions. Provide current requirements for power pins and the routing constraints near the connector.
What to Put on the Cable Assembly Drawing
- Connector and mating views Record the manufacturer and full part number at each end. Mark pin 1 and state whether each diagram shows the mating face or the wire-entry side.
- Pin assignments List every populated contact, pair polarity, power and ground positions, and intentional opens. State whether the cable is straight-through or uses a custom pin map.
- Wire and impedance Specify wire type, AWG or approved wire part number, and single-ended or differential impedance as applicable. Include length matching or skew limits when required.
- Length and routing Define the measurement points, finished length tolerance, cable breakout, and exit direction. Include bends, pass-through dimensions, and any moving sections.
- Shielding and protection Define individual shield and shell connections at both ends. Specify sleeve type, wrapping, jacket, labels, and strain relief where needed.
Prototype Review and Production Checks
- First article Review the mating fit, cable routing, connector orientation, and overall dimensions against the drawing before releasing the production configuration.
- Electrical inspection Specify pin-to-pin continuity, shorts between conductors, and shield continuity. Where the drawing calls for isolation, identify the relevant conductors and limits.
- Signal integrity If the project requires impedance, insertion loss, or skew measurements, state the test method, reference points, and acceptance limits in the RFQ.
Frequently Asked Questions
Can the two ends use different connector families?
Yes, where the application is electrically and mechanically compatible. Include both mating-face drawings, the exact part number at each end, and a pin-by-pin mapping.
What should be checked when copying an existing CABLINE-CAL cable?
Confirm the 30- or 40-position interface, the latch orientation, and the wiring at both ends. Send an existing sample or mating-face photos if the drawing is unavailable.
Can I use fewer wires than the connector has positions?
Yes, if your design allows it. Mark intentionally unpopulated positions and specify any grounds or shields that still need termination. Send the full pin map for both ends so the wiring can be checked before production.
Request an I-PEX 20728 Cable Assembly Quote
Send both connector part numbers, the assembly drawing, wire gauge or impedance, and prototype and production quantities. If a drawing is unavailable, send clear photographs of both connector faces, cable labels, and the original assembly.