I-PEX 20681 CABLINE-CA II Lock Bar Assembly for Micro-Coax Harnesses
The I-PEX 20681 is the lock bar assembly in the CABLINE-CA II family, which uses a 0.4 mm contact pitch and horizontal mating. PrecisionCoax builds custom micro-coax cable harnesses for this connector system for projects such as shielded camera links, industrial display wiring, and internal high-speed interconnects.
Connector Selection at a Glance
- Connector family I-PEX CABLINE-CA II.
- Listed contact counts 20, 30, 40, 50.
- Selection notes The lock bar is one part of the cable-side plug assembly. For installed equipment, check the path needed to engage and release it, including enclosure and bundle clearance.
I-PEX 20681 Part Numbers and Connector Options
The 20681 is the lock bar assembly for a 20679 plug. Choose a matching position count for the plug housing and lock bar, and identify the board receptacle before approving a replacement assembly.
Related part families include 20679 (cable-side plug), 20680 (plug housing), 20682 (PCB receptacle).
The following are publicly documented part numbers, including some earlier variants. Confirm the exact suffix and availability for your project.
- 20 positions: 20681-020T-01
- 30 positions: 20681-030T-01
- 40 positions: 20681-040T-01
- 50 positions: 20681-050T-01
Wire Selection and Custom Harness Options
The CABLINE-CA II catalog references 38 AWG or finer micro-coax for 45-ohm single-ended signals and 40 AWG or finer for 50-ohm single-ended signals. Final wire selection depends on the exact connector, cable outer diameter, and termination dimensions.
When ordering a finished harness, identify the plug housing, lock bar and board receptacle. Include the latch release direction and any pull-tape length or routing requirements in the mechanical drawing.
The original CABLINE-CA II catalog shows 20-, 30-, 40-, and 50-position plug assemblies. For a 60-position project, identify whether the BOM specifies the CABLINE-CA II PLUS system.
Specify the preferred sleeving, cable jacket, shield grounding, and routing. Inspection requirements can include pin-to-pin continuity, shorts, and shield continuity.
Harness Applications and Service Access
Shielded camera or imaging cable
Show where each individual shield terminates and where the plug shell bonds to chassis or circuit ground. Define any isolation requirements in the drawing.
High-speed board-to-board cable with a mechanical lock
Provide space to insert the plug, operate the lock, and route the bundle. Define high-speed pairs and the acceptance criteria for the assembled link.
What to Put on the Cable Assembly Drawing
- Connector and mating views Record the manufacturer and full part number at each end. Mark pin 1 and state whether each diagram shows the mating face or the wire-entry side.
- Pin assignments List every populated contact, pair polarity, power and ground positions, and intentional opens. State whether the cable is straight-through or uses a custom pin map.
- Wire and impedance Specify wire type, AWG or approved wire part number, and single-ended or differential impedance as applicable. Include length matching or skew limits when required.
- Length and routing Define the measurement points, finished length tolerance, cable breakout, and exit direction. Include bends, pass-through dimensions, and any moving sections.
- Shielding and protection Define individual shield and shell connections at both ends. Specify sleeve type, wrapping, jacket, labels, and strain relief where needed.
Prototype Review and Production Checks
- First article Review the mating fit, cable routing, connector orientation, and overall dimensions against the drawing before releasing the production configuration.
- Electrical inspection Specify pin-to-pin continuity, shorts between conductors, and shield continuity. Where the drawing calls for isolation, identify the relevant conductors and limits.
- Signal integrity If the project requires impedance, insertion loss, or skew measurements, state the test method, reference points, and acceptance limits in the RFQ.
Frequently Asked Questions
How do I specify the lock bar on a cable drawing?
List the complete lock bar and housing part numbers, and show the access direction. If a pull tape is specified, mark its exit direction and the room available to grasp it.
How do I identify a replacement when the old cable carries only a partial label?
Send the label and clear photos of the housing, lock bar, and mating board connector. Include the number of positions and available installation clearance.
Can I use fewer wires than the connector has positions?
Yes, if your design allows it. Mark intentionally unpopulated positions and specify any grounds or shields that still need termination. Send the full pin map for both ends so the wiring can be checked before production.
Request an I-PEX 20681 Cable Assembly Quote
Send the lock bar, housing, and receptacle part numbers, plus the wire gauge, pin map, finished length, and desired quantities. If a drawing is unavailable, send clear photographs of both connector faces, cable labels, and the original assembly.