I-PEX 20533 CABLINE-UX II PCB Receptacle for Micro-Coax Harnesses
The I-PEX 20533 is the PCB receptacle in the CABLINE-UX II family, which uses a 0.25 mm contact pitch and right-angle vertical mating. PrecisionCoax builds custom micro-coax cable harnesses for this connector system for projects such as tight hinge passages, compact camera harnesses, and dense internal wiring.
Connector Selection at a Glance
- Connector family I-PEX CABLINE-UX II.
- Listed contact counts 30, 34, 40, 50.
- Selection notes The part number identifies the PCB-side interface. Use it to confirm the mating cable-side plug. For existing boards, include the board revision and a clear mating-face photo.
I-PEX 20533 Part Numbers and Connector Options
I-PEX identifies 20533-230E, 20533-234E, 20533-240E, and 20533-250E as 30-, 34-, 40-, and 50-position PCB receptacles, respectively. The first digit in these part-number blocks does not represent the contact count.
Related part families include 20531 (cable-side plug), 20532 (plug housing).
The following are publicly documented part numbers, including some earlier variants. Confirm the exact suffix and availability for your project.
- 30 positions: 20533-230E
- 34 positions: 20533-234E
- 40 positions: 20533-240E
- 50 positions: 20533-250E
Wire Selection and Custom Harness Options
I-PEX documentation for CABLINE-UX II references micro-coaxial wire in 44 and 46 AWG. Final wire selection depends on the exact connector, cable outer diameter, termination dimensions, and electrical requirements.
A receptacle number identifies the board interface. We use it to check the cable-side plug and then build the micro-coax harness to the pinout and cable routing you specify.
The connector contact pitch is 0.25 mm, and the specified board pitch is 0.5 mm. Provide the hinge opening, exit direction, and any cable flex or bend-radius requirement.
Specify the preferred sleeving, cable jacket, shield grounding, and routing. Inspection requirements can include pin-to-pin continuity, shorts, and shield continuity.
Applications for the Mating Cable Assembly
Micro-coax cable through a hinge
Specify how the hinge moves, where the cable is supported, and the narrowest opening the assembled harness must pass through.
Compact camera or sensor interconnect
Define allowable cable bundle diameter and where the first bend can start. Mark power, return, and signal positions so that wire sizes can be reviewed alongside the pin map.
What to Put on the Cable Assembly Drawing
- Connector and mating views Record the manufacturer and full part number at each end. Mark pin 1 and state whether each diagram shows the mating face or the wire-entry side.
- Pin assignments List every populated contact, pair polarity, power and ground positions, and intentional opens. State whether the cable is straight-through or uses a custom pin map.
- Wire and impedance Specify wire type, AWG or approved wire part number, and single-ended or differential impedance as applicable. Include length matching or skew limits when required.
- Length and routing Define the measurement points, finished length tolerance, cable breakout, and exit direction. Include bends, pass-through dimensions, and any moving sections.
- Shielding and protection Define individual shield and shell connections at both ends. Specify sleeve type, wrapping, jacket, labels, and strain relief where needed.
Prototype Review and Production Checks
- First article Review the mating fit, cable routing, connector orientation, and overall dimensions against the drawing before releasing the production configuration.
- Electrical inspection Specify pin-to-pin continuity, shorts between conductors, and shield continuity. Where the drawing calls for isolation, identify the relevant conductors and limits.
- Signal integrity If the project requires impedance, insertion loss, or skew measurements, state the test method, reference points, and acceptance limits in the RFQ.
Frequently Asked Questions
Can I order a harness from the PCB receptacle part number alone?
The receptacle is a starting point for selecting the mating plug. A harness quote also needs the second connector or termination, finished length, pin map, and cable requirements.
Can I use a thicker cable if the pin map stays the same?
Check conductor and insulation dimensions, shell clearance, and overall bundle size before making a change. The harness drawing should identify the exact wire selected.
Can I use fewer wires than the connector has positions?
Yes, if your design allows it. Mark intentionally unpopulated positions and specify any grounds or shields that still need termination. Send the full pin map for both ends so the wiring can be checked before production.
Request an I-PEX 20533 Cable Assembly Quote
Send the full receptacle number, the connector at the opposite end, the two pinouts, finished cable length, and order quantities. If a drawing is unavailable, send clear photographs of both connector faces, cable labels, and the original assembly.






