I-PEX 20524 CABLINE-CA Plug Housing & Cable Harness
I-PEX 20524 CABLINE-CA plug housing and custom micro-coax harnesses. Review models including 20524-030T-01, mating parts, and cable options.
  • Country of Origin: China
  • Certification: UL, ISO13485, ISO9001
  • MOQ: negotiable
  • Price: Best price
  • Packaging details: PE inner layer, carton outer layer
  • Delivery time: 7-15 days after payment received
  • Payment method: T/T, Western Union
  • Supply capacity: 500,000 pieces/week

Partner Brands

I-PEX 20524 CABLINE-CA Plug Housing for Micro-Coax Harnesses

The I-PEX 20524 is the plug housing in the CABLINE-CA family, which uses a 0.4 mm contact pitch and horizontal mating. PrecisionCoax builds custom micro-coax cable harnesses for this connector system for projects such as embedded display harnesses, board-to-module wiring, and custom high-speed adapters.

Connector Selection at a Glance

  • Connector family I-PEX CABLINE-CA.
  • Listed contact counts 12, 20, 30, 40, 50, 60.
  • Selection notes Use the housing number to identify the contact set and its plug configuration. A finished cable drawing should also identify the metal shell, retention hardware where applicable, and board receptacle.

I-PEX 20524 Part Numbers and Connector Options

The 20524 is an earlier CABLINE-CA plug housing. I-PEX lists selected 30-, 40-, and 50-position 20524 parts with 20634 alternatives. Differences can include wire capacity and contact plating, so validate any BOM change against the original harness drawing.

Related part families include 20523 (cable-side plug), 20525 (PCB receptacle), 20634 (plug housing).

The following are publicly documented part numbers, including some earlier variants. Confirm the exact suffix and availability for your project.

  • 12 positions: 20524-112T-02
  • 20 positions: 20524-120T-02, 20524-120T-02-A
  • 30 positions: 20524-030T-01, 20524-130T-02, 20524-130T-02-A
  • 40 positions: 20524-040T-01, 20524-140T-02
  • 50 positions: 20524-050T-02
  • 60 positions: 20524-060T-02, 20524-160T-02

Wire Selection and Custom Harness Options

I-PEX documentation for CABLINE-CA references micro-coaxial wire in 36, 38, 40, 42, and 44 AWG. Final wire selection depends on the exact connector, cable outer diameter, termination dimensions, and electrical requirements.

For a complete micro-coax harness, identify the plug housing, shell, mating receptacle, and any retention hardware. We review conductor sizes, cable exit direction, and the shield termination shown in the drawing.

CABLINE-CA uses multiple plug and receptacle combinations. Include the existing board-side suffix and identify each high-speed pair and shield ground before assigning wires.

Specify the preferred sleeving, cable jacket, shield grounding, and routing. Inspection requirements can include pin-to-pin continuity, shorts, and shield continuity.

Common Harness Designs Using This Housing

Board-to-module micro-coax harness

For a link between two boards, specify the pin numbering views on both connectors. Mark differential pair polarity, power and return pins, and any unused positions.

Custom display or high-speed adapter cable

If a controller, carrier, or display adapter uses different connectors at each end, provide both interface specifications. State the target impedance and any limits on assembly length or individual conductor length.

What to Put on the Cable Assembly Drawing

  • Connector and mating views Record the manufacturer and full part number at each end. Mark pin 1 and state whether each diagram shows the mating face or the wire-entry side.
  • Pin assignments List every populated contact, pair polarity, power and ground positions, and intentional opens. State whether the cable is straight-through or uses a custom pin map.
  • Wire and impedance Specify wire type, AWG or approved wire part number, and single-ended or differential impedance as applicable. Include length matching or skew limits when required.
  • Length and routing Define the measurement points, finished length tolerance, cable breakout, and exit direction. Include bends, pass-through dimensions, and any moving sections.
  • Shielding and protection Define individual shield and shell connections at both ends. Specify sleeve type, wrapping, jacket, labels, and strain relief where needed.

Prototype Review and Production Checks

  • First article Review the mating fit, cable routing, connector orientation, and overall dimensions against the drawing before releasing the production configuration.
  • Electrical inspection Specify pin-to-pin continuity, shorts between conductors, and shield continuity. Where the drawing calls for isolation, identify the relevant conductors and limits.
  • Signal integrity If the project requires impedance, insertion loss, or skew measurements, state the test method, reference points, and acceptance limits in the RFQ.

Frequently Asked Questions

What should I include if my BOM lists only the plug housing?

Provide the housing suffix, the board receptacle number, and any shell or latch information from the original assembly. Photos of an assembled plug can help identify missing BOM details.

How should I specify a 90-ohm differential cable design?

Identify whether the specified impedance is differential or single-ended, provide the pair mapping, and state the required measurement method if applicable. The quoted wire and finished assembly will be selected against those requirements.

Can I use fewer wires than the connector has positions?

Yes, if your design allows it. Mark intentionally unpopulated positions and specify any grounds or shields that still need termination. Send the full pin map for both ends so the wiring can be checked before production.

Request an I-PEX 20524 Cable Assembly Quote

Send the full housing number, plug or shell numbers if available, mating receptacle, cable length, pin map, and required quantities. If a drawing is unavailable, send clear photographs of both connector faces, cable labels, and the original assembly.

Product Ordering Guidelines

For Existing Product Designs or Samples

If you already have product drawings or physical samples, simply provide them to us, and we can proceed with production.

Custom Product Development (No Existing Reference)

If you need to develop a new product without existing samples or drawings, please provide the following details for our design team to create a tailored solution:
a. Electrical Requirements: Operating current and voltage.
b. Connector Specifications: Model numbers, samples, or specifications for connectors at both ends of the cable.
c. Pin Configuration: Pin-to-pin correspondence for the cable assembly.
d. Environmental Conditions: Application scenario (e.g., lawn mowers, mining equipment) and required certifications (oil resistance, waterproofing, high-temperature tolerance, flexing tests, etc.).
e. Electrical Testing Requirements: Transmission characteristics, voltage withstand, conduction resistance, insulation resistance, etc.

Custom Cables & Solutions

Specializing in small-batch, multi-variety production! We offer end-to-end services, from new product introduction to mass production.

Core Advantages

✓ 20+ Years of Brand-Component Distribution Expertise
✓ 100% Genuine Components Direct from Original Manufacturers
✓ Expert Product Selection & Matching Services

Rapid Delivery from Stock

Domestic Warehouse: Orders placed today, shipped tomorrow.
International Warehouse: Orders placed today, delivered in 6-10 days.

Ordering Flexibility

✓ Minimum Order: 1 unit
✓ Small-Batch Samples: Available from 1 unit
✓ Large-Scale Orders: Standard lead time from original manufacturers.

Key Features

✓ Minimum Order: 1 unit
Small-Quantity Friendly: Ideal for prototyping and niche projects.
Bulk Order Efficiency: Seamless scaling from trial to mass production.

Scroll