I-PEX 20523 CABLINE-CA Micro-Coaxial Cable Assemblies
PrecisionCoax builds custom micro-coaxial cable assemblies using the I-PEX 20523 CABLINE-CA cable-side plug. The family uses a 0.4 mm contact pitch with horizontal mating and can be evaluated for embedded display harnesses, board-to-module wiring, and custom high-speed adapters.
Connector Selection at a Glance
- Connector family I-PEX CABLINE-CA.
- Listed contact counts 30, 50.
- Selection notes The plug part number identifies the cable-side termination. Use the confirmed plug and board receptacle combination before choosing a cable layout.
I-PEX 20523 Part Numbers and Connector Options
The 20523 identifies an earlier CABLINE-CA plug. I-PEX also catalogs the 20523-0xxT-01, 20523-0xxT-01S, and 20523-2xxT-01S patterns. For an older harness, use the exact 20523 number and the original 20525 receptacle to check the cable BOM.
Related part families include 20524 (plug housing), 20525 (PCB receptacle), 20633 (cable-side plug).
The following are publicly documented part numbers, including some earlier variants. Confirm the exact suffix and availability for your project.
- 30 positions: 20523-030T-01, 20523-230T-01
- 50 positions: 20523-050T-01S
Wire Selection and Custom Harness Options
I-PEX documentation for CABLINE-CA references micro-coaxial wire in 36, 38, 40, 42, and 44 AWG. Final wire selection depends on the exact connector, cable outer diameter, termination dimensions, and electrical requirements.
Specify the finished length, plug orientation at each end, and straight-through or custom pin mapping. If the opposite end uses a different connector, include its exact part number and mating view.
CABLINE-CA uses multiple plug and receptacle combinations. Include the existing board-side suffix and identify each high-speed pair and shield ground before assigning wires.
Specify the preferred sleeving, cable jacket, shield grounding, and routing. Inspection requirements can include pin-to-pin continuity, shorts, and shield continuity.
Typical Cable Assembly Applications
Board-to-module micro-coax harness
For a link between two boards, specify the pin numbering views on both connectors. Mark differential pair polarity, power and return pins, and any unused positions.
Custom display or high-speed adapter cable
If a controller, carrier, or display adapter uses different connectors at each end, provide both interface specifications. State the target impedance and any limits on assembly length or individual conductor length.
What to Put on the Cable Assembly Drawing
- Connector and mating views Record the manufacturer and full part number at each end. Mark pin 1 and state whether each diagram shows the mating face or the wire-entry side.
- Pin assignments List every populated contact, pair polarity, power and ground positions, and intentional opens. State whether the cable is straight-through or uses a custom pin map.
- Wire and impedance Specify wire type, AWG or approved wire part number, and single-ended or differential impedance as applicable. Include length matching or skew limits when required.
- Length and routing Define the measurement points, finished length tolerance, cable breakout, and exit direction. Include bends, pass-through dimensions, and any moving sections.
- Shielding and protection Define individual shield and shell connections at both ends. Specify sleeve type, wrapping, jacket, labels, and strain relief where needed.
Prototype Review and Production Checks
- First article Review the mating fit, cable routing, connector orientation, and overall dimensions against the drawing before releasing the production configuration.
- Electrical inspection Specify pin-to-pin continuity, shorts between conductors, and shield continuity. Where the drawing calls for isolation, identify the relevant conductors and limits.
- Signal integrity If the project requires impedance, insertion loss, or skew measurements, state the test method, reference points, and acceptance limits in the RFQ.
Frequently Asked Questions
Can the two ends use different connector families?
Yes, where the application is electrically and mechanically compatible. Include both mating-face drawings, the exact part number at each end, and a pin-by-pin mapping.
How should I specify a 90-ohm differential cable design?
Identify whether the specified impedance is differential or single-ended, provide the pair mapping, and state the required measurement method if applicable. The quoted wire and finished assembly will be selected against those requirements.
Can I use fewer wires than the connector has positions?
Yes, if your design allows it. Mark intentionally unpopulated positions and specify any grounds or shields that still need termination. Send the full pin map for both ends so the wiring can be checked before production.
Request an I-PEX 20523 Cable Assembly Quote
Send both connector part numbers, the assembly drawing, wire gauge or impedance, and prototype and production quantities. If a drawing is unavailable, send clear photographs of both connector faces, cable labels, and the original assembly.