Micro Coaxial Cable Processing Specialist

Room 409, Room 4, Hatching Building, No. 98 Xiongtian Road, Longping High-tech Park, Furong District, Changsha City, Changsha City

© Copyright 2025 PrecisionCoax

I-PEX 20498 CABLINE-UA II PCB Receptacle & Mating Cable
I-PEX 20498 CABLINE-UA II PCB receptacle and mating micro-coax cable. Compare models including 20498-026E-41 and request a custom harness quote.
  • Country of Origin: China
  • Certification: UL, ISO13485, ISO9001
  • MOQ: negotiable
  • Price: Best price
  • Packaging details: PE inner layer, carton outer layer
  • Delivery time: 7-15 days after payment received
  • Payment method: T/T, Western Union
  • Supply capacity: 500,000 pieces/week

Partner Brands

I-PEX 20498 CABLINE-UA II PCB Receptacle for Micro-Coax Harnesses

The I-PEX 20498 is the PCB receptacle in the CABLINE-UA II family, which uses a 0.3 mm contact pitch and right-angle vertical mating. PrecisionCoax builds custom micro-coax cable harnesses for this connector system for projects such as compact imaging modules and hinge-routed display wiring.

Connector Selection at a Glance

  • Connector family I-PEX CABLINE-UA II.
  • Listed contact counts 26, 32, 40, 50.
  • Selection notes The part number identifies the PCB-side interface. Use it to confirm the mating cable-side plug. For existing boards, include the board revision and a clear mating-face photo.

I-PEX 20498 Part Numbers and Connector Options

The 20498 is the board-side receptacle. Drawing combinations pair 20496 -30 plugs with 20498 -3-series receptacles and 20496 -40 plugs with 20498 -4-series receptacles. Check the complete receptacle suffix for the board.

Related part families include 20496 (cable-side plug), 20497 (plug housing).

The following are publicly documented part numbers, including some earlier variants. Confirm the exact suffix and availability for your project.

  • 26 positions: 20498-026E-00, 20498-026E-01, 20498-026E-20-C, 20498-026E-21, 20498-026E-30, 20498-026E-31, 20498-026E-40, 20498-026E-41, 20498-R26E-30, 20498-R26E-31, 20498-R26E-40, 20498-R26E-41
  • 32 positions: 20498-032E-00, 20498-032E-01, 20498-032E-30, 20498-032E-31, 20498-032E-40, 20498-032E-41, 20498-R32E-30, 20498-R32E-31, 20498-R32E-40, 20498-R32E-41
  • 40 positions: 20498-040E-00, 20498-040E-01, 20498-040E-30, 20498-040E-31, 20498-040E-40, 20498-040E-41, 20498-R40E-30, 20498-R40E-31, 20498-R40E-40, 20498-R40E-41
  • 50 positions: 20498-050E-00, 20498-050E-01, 20498-050E-30, 20498-050E-31, 20498-050E-40, 20498-050E-41, 20498-R50E-30, 20498-R50E-31, 20498-R50E-40, 20498-R50E-41

Wire Selection and Custom Harness Options

I-PEX documentation for CABLINE-UA II references micro-coaxial wire in 42, 44, and 46 AWG. Final wire selection depends on the exact connector, cable outer diameter, termination dimensions, and electrical requirements.

A receptacle number identifies the board interface. We use it to check the cable-side plug and then build the micro-coax harness to the pinout and cable routing you specify.

The contact pitch is 0.3 mm, and the catalog lists a separate 0.6 mm board pitch. For designs with a narrow pass-through, provide the opening dimensions and the maximum finished bundle diameter.

Specify the preferred sleeving, cable jacket, shield grounding, and routing. Inspection requirements can include pin-to-pin continuity, shorts, and shield continuity.

Applications for the Mating Cable Assembly

Compact imaging module harness

Identify each signal, return, and shield position. Show the connector exit direction so the bundle can be routed clear of neighboring components.

Fine-pitch cable through a narrow opening

Give the minimum opening in both directions, and show whether the finished connector or only the cable bundle must pass through it.

What to Put on the Cable Assembly Drawing

  • Connector and mating views Record the manufacturer and full part number at each end. Mark pin 1 and state whether each diagram shows the mating face or the wire-entry side.
  • Pin assignments List every populated contact, pair polarity, power and ground positions, and intentional opens. State whether the cable is straight-through or uses a custom pin map.
  • Wire and impedance Specify wire type, AWG or approved wire part number, and single-ended or differential impedance as applicable. Include length matching or skew limits when required.
  • Length and routing Define the measurement points, finished length tolerance, cable breakout, and exit direction. Include bends, pass-through dimensions, and any moving sections.
  • Shielding and protection Define individual shield and shell connections at both ends. Specify sleeve type, wrapping, jacket, labels, and strain relief where needed.

Prototype Review and Production Checks

  • First article Review the mating fit, cable routing, connector orientation, and overall dimensions against the drawing before releasing the production configuration.
  • Electrical inspection Specify pin-to-pin continuity, shorts between conductors, and shield continuity. Where the drawing calls for isolation, identify the relevant conductors and limits.
  • Signal integrity If the project requires impedance, insertion loss, or skew measurements, state the test method, reference points, and acceptance limits in the RFQ.

Frequently Asked Questions

Can I order a harness from the PCB receptacle part number alone?

The receptacle is a starting point for selecting the mating plug. A harness quote also needs the second connector or termination, finished length, pin map, and cable requirements.

Which spacing should I use on the assembly drawing?

Use the I-PEX drawing for the exact orderable part. The connector contact pitch and the PCB termination pitch are separate dimensions on this family.

Can I use fewer wires than the connector has positions?

Yes, if your design allows it. Mark intentionally unpopulated positions and specify any grounds or shields that still need termination. Send the full pin map for both ends so the wiring can be checked before production.

Request an I-PEX 20498 Cable Assembly Quote

Send the full receptacle number, the connector at the opposite end, the two pinouts, finished cable length, and order quantities. If a drawing is unavailable, send clear photographs of both connector faces, cable labels, and the original assembly.

Product Ordering Guidelines

For Existing Product Designs or Samples

If you already have product drawings or physical samples, simply provide them to us, and we can proceed with production.

Custom Product Development (No Existing Reference)

If you need to develop a new product without existing samples or drawings, please provide the following details for our design team to create a tailored solution:
a. Electrical Requirements: Operating current and voltage.
b. Connector Specifications: Model numbers, samples, or specifications for connectors at both ends of the cable.
c. Pin Configuration: Pin-to-pin correspondence for the cable assembly.
d. Environmental Conditions: Application scenario (e.g., lawn mowers, mining equipment) and required certifications (oil resistance, waterproofing, high-temperature tolerance, flexing tests, etc.).
e. Electrical Testing Requirements: Transmission characteristics, voltage withstand, conduction resistance, insulation resistance, etc.

Custom Cables & Solutions

Specializing in small-batch, multi-variety production! We offer end-to-end services, from new product introduction to mass production.

Core Advantages

✓ 20+ Years of Brand-Component Distribution Expertise
✓ 100% Genuine Components Direct from Original Manufacturers
✓ Expert Product Selection & Matching Services

Rapid Delivery from Stock

Domestic Warehouse: Orders placed today, shipped tomorrow.
International Warehouse: Orders placed today, delivered in 6-10 days.

Ordering Flexibility

✓ Minimum Order: 1 unit
✓ Small-Batch Samples: Available from 1 unit
✓ Large-Scale Orders: Standard lead time from original manufacturers.

Key Features

✓ Minimum Order: 1 unit
Small-Quantity Friendly: Ideal for prototyping and niche projects.
Bulk Order Efficiency: Seamless scaling from trial to mass production.

Scroll