I-PEX 20453 CABLINE-VS Micro-Coaxial Cable Assemblies
PrecisionCoax builds custom micro-coaxial cable assemblies using the I-PEX 20453 CABLINE-VS cable-side plug. The family uses a 0.5 mm contact pitch with horizontal mating and can be evaluated for LCD panel wiring, embedded display cables, and legacy LVDS or eDP harness projects.
Connector Selection at a Glance
- Connector family I-PEX CABLINE-VS.
- Listed contact counts 20, 30, 40, 50.
- Selection notes The plug part number identifies the cable-side termination. Use the confirmed plug and board receptacle combination before choosing a cable layout.
I-PEX 20453 Part Numbers and Connector Options
The 20453 plug is offered across 20, 30, 40, and 50 positions. The specification distinguishes 0xxT, 2xxT, and 3xxT plug combinations with separate receptacle suffix groups. Verify the board-side version before ordering, including for 20453-230T-03 and 20453-240T-03.
Related part families include 20454 (plug housing), 20455 (PCB receptacle).
The following are publicly documented part numbers, including some earlier variants. Confirm the exact suffix and availability for your project.
- 20 positions: 20453-020T-03, 20453-220T-03, 20453-320T-13
- 30 positions: 20453-030T-03, 20453-230T-03, 20453-330T-13
- 40 positions: 20453-040T-03, 20453-240T-03, 20453-340T-13
- 50 positions: 20453-050T-01S, 20453-050T-03S, 20453-050T-11S, 20453-250T-01S, 20453-250T-03S, 20453-250T-11S, 20453-350T-13S
Wire Selection and Custom Harness Options
I-PEX documentation for CABLINE-VS references micro-coaxial wire in 36, 38, 40, 42, and 44 AWG. Final wire selection depends on the exact connector, cable outer diameter, termination dimensions, and electrical requirements.
Specify the finished length, plug orientation at each end, and straight-through or custom pin mapping. If the opposite end uses a different connector, include its exact part number and mating view.
The CABLINE-VS specification separates the plug and receptacle combinations by their suffixes. For a panel replacement, provide the screen and motherboard connector numbers and the pin 1 orientation at both ends.
Specify the preferred sleeving, cable jacket, shield grounding, and routing. Inspection requirements can include pin-to-pin continuity, shorts, and shield continuity.
Typical Cable Assembly Applications
LCD panel replacement cable
Provide the LCD panel and controller part numbers. Identify data lanes, panel power, grounds, and any backlight connections in the pin map.
eDP or LVDS panel harness
Specify the display protocol on each end and include both pinouts. A passive cable can route signals between compatible interfaces. Protocol conversion requires separate electronics.
What to Put on the Cable Assembly Drawing
- Connector and mating views Record the manufacturer and full part number at each end. Mark pin 1 and state whether each diagram shows the mating face or the wire-entry side.
- Pin assignments List every populated contact, pair polarity, power and ground positions, and intentional opens. State whether the cable is straight-through or uses a custom pin map.
- Wire and impedance Specify wire type, AWG or approved wire part number, and single-ended or differential impedance as applicable. Include length matching or skew limits when required.
- Length and routing Define the measurement points, finished length tolerance, cable breakout, and exit direction. Include bends, pass-through dimensions, and any moving sections.
- Shielding and protection Define individual shield and shell connections at both ends. Specify sleeve type, wrapping, jacket, labels, and strain relief where needed.
Prototype Review and Production Checks
- First article Review the mating fit, cable routing, connector orientation, and overall dimensions against the drawing before releasing the production configuration.
- Electrical inspection Specify pin-to-pin continuity, shorts between conductors, and shield continuity. Where the drawing calls for isolation, identify the relevant conductors and limits.
- Signal integrity If the project requires impedance, insertion loss, or skew measurements, state the test method, reference points, and acceptance limits in the RFQ.
Frequently Asked Questions
Can the two ends use different connector families?
Yes, where the application is electrically and mechanically compatible. Include both mating-face drawings, the exact part number at each end, and a pin-by-pin mapping.
Does the same pin count mean two display cables have the same pinout?
Connector size only tells you how many positions are available. Compare pin numbering, signal polarity, and power positions on the panel and controller, and check the exact plug and receptacle suffix.
Can I use fewer wires than the connector has positions?
Yes, if your design allows it. Mark intentionally unpopulated positions and specify any grounds or shields that still need termination. Send the full pin map for both ends so the wiring can be checked before production.
Request an I-PEX 20453 Cable Assembly Quote
Send both connector part numbers, the assembly drawing, wire gauge or impedance, and prototype and production quantities. If a drawing is unavailable, send clear photographs of both connector faces, cable labels, and the original assembly.






